With a mobile device, SMS the configuration message to the SIM card's phone number:
AT+QICSGP="mode","apn","username","password"
Because you made sure the SIM card is simlock free, the last 2 fields remain empty, but the comma's and quote's need to be there to indicate the empty fields.
So the actual SMS message looks like this:
AT+QICSGP=1,"APN","",""
Mode is 1 by default and APN needs to be replaced by the APN you received from your SIM card provider.
If it works, the SIM card will reply with "OK".
It can take up to 30 minutes before the inverter shows online.
If you encounter any problems, please contact our support department in your country and/or create a support ticket.