DSP Update Procedure
Prepare USB Stick
- Place
20862API.bin
and20862APP.bin
files on a USB stick, ensuring20862APP.bin
is named correctly and not in a folder or zipped. - Ensure no other files are on the USB stick.
- Place
Connect Firmware Update Tool
- Insert USB into the Firmware Update Tool and connect to the inverter's 4-pin green port.
- The tool should light up red and green.
Inverter Settings
- On the inverter display, go to Advanced Settings, enter password
0010
, select "Turn Grid On/Off," and turn it OFF. - Return to Advanced Settings, enter the password again, and select DSP Update. Verify the current version.
- On the inverter display, go to Advanced Settings, enter password
Initiate DSP Update
- Select Enter on DSP Update. The green light on the tool should start flashing.
- Press the button on the Firmware Update Tool to begin the update. Watch for the green light to flash rapidly, then slowly.
Completion
- When the green and red lights turn solid, the update is complete.
- If the green light goes dark and then reappears after 4–5 seconds, the update was successful.
- Verify the version change after the inverter’s LCD operation light stops blinking.
Turn Grid Back On
- In Advanced Settings, enter password
0010
, select "Turn Grid On/Off," and turn it ON if production is ready.
- In Advanced Settings, enter password
HMI Update Procedure
Prepare USB Stick
- Place the
HMI.bin
orHMI_WIFI.bin
file on a USB stick, ensuring it is named correctly and not zipped.
- Place the
Connect Firmware Update Tool
- Insert the USB into the Firmware Update Tool and connect it to the inverter’s 4-pin Green Port. The tool should light up red and green.
Inverter Settings
- On the inverter display, go to Advanced Settings, enter password
0010
, and turn the grid OFF. - Go back to Advanced Settings, enter password again, select HMI Update, and ensure no communication cables are connected, with the address set to 1.
- On the inverter display, go to Advanced Settings, enter password
Initiate HMI Update
- Hold the button on the Firmware Update Tool until all lights are lit, then release.
- In Advanced Settings, select HMI Update and enter Update Mode. The screen will go blank, and the green light should flash.
- Press the Firmware Update Tool button to start the update, verifying that the green light flashes quickly, then slowly.
Completion
- When the green light is solid, the update is complete.
- If the green light briefly turns off and then reappears after 4–5 seconds, the update was successful.
- Confirm the version change once the inverter LCD stops blinking.
Turn Grid Back On
- In Advanced Settings, enter password
0010
, select "Turn Grid On/Off," and turn it ON if ready to resume production.
- In Advanced Settings, enter password
This summary captures the essential steps for updating DSP and HMI firmware on a Solis on-grid inverter. Following these instructions ensures the device remains updated and ready for optimal operation.