Eastron Meter Ratio Issue with Single Phase Hybrid Inverters
Summary:
There is a known issue where the Eastron meter ratio does not match correctly with single-phase hybrid inverters due to a supplier configuration error. This results in incorrect meter ratio readings on the system.
Impact
Incorrect meter ratio may cause inaccurate energy reporting in Soliscloud.
Users may see discrepancies in imported/exported energy values.
Root Cause
Supplier configuration mismatch between Eastron meters and single-phase hybrid inverter settings.
Resolution
To correct the meter ratio, follow the updated instructions provided on Soliscloud. These instructions ensure the meter is set up correctly.
Steps:
1. Watch the video: See attachement
2.Log in to Soliscloud and navigate to the affected inverter.
3. Check for the Important Notice pop-up:
4. “To ensure the meter is set up correctly, please be sure to check the installation instructions.”
5. Click on Installation instructions > and follow the detailed steps to adjust the meter ratio.
![]() | ![]() | ![]() |
6. Confirm the ratio matches the inverter specifications after adjustment.